Fluid Mechanics Lab

Fluid Mechanics Lab

Grid View:
Quickview

BERNOULLI'S THEOREM

(0)
₹2.0

Set up consists of a one piece clear acrylic test section with convergent and divergentpart section, supply tank, measuring tank, inlet water tank and pump for closed loopwater circulation. The test section is connected to Piezometer tubes through pressuretapping at different locations on the section to demonstrate the Bernoulli’s Theorem.The flow ..

Quickview

DISCHARGE OVER NOTCHES

(0)
₹2.0

Required Notch is fitted at one end of this channel .A hook gauge with Vernier scale isfitted to measure the height of fluid in flow channel. Arrangement for fixinginterchangeable notches is made. Set of three brass notches, i.e. rectangular notch. 60V notch & 45 V notch provided along with the set up. Present set – up is self –containedwater r..

Quickview

FLOW MEASUREMENT DEVICES

(0)
₹2.0

Measurement of liquid flow is required at various places and for various purposes. Differenttypes of flow measuring devices are used depending upon the system conditions, accuracyrequired, skill of operator and economy desired. The unit demonstrates some of the flowmeasurement devices.SPECIFICATIONS:[1] Intergratiry Type Turbine flow meter.[2] Glas..

Quickview

FREE AND FORCE VORTEX

(0)
₹2.0

DESCRIPTION:- The experimental set up consist of a circular transparent cylindrical tankin which four circumferential jets have been placed along the circumference of thecylinder near its bottom which helps in the formation of free vortex. It is assumed that thetorque exerted by these jets is negligible. The Orifice is reducing bush so that a reduc..

Quickview

FRICTION IN PIPE LINES

(0)
₹2.0

The Set-up consists of 2 pipes of different diameters, which are connected in parallel.Pressure tapings are provided on each pipe to measure the pressure losses with the helpof a Differential Manometer. Control valves are fitted on each pipe, which enables to useone pipe at a time for experiment. Present set-up is self-contained water re-circulatin..

Quickview

IMPACT OF JET ON VANES

(0)
₹2.0

DESCRIPTION:- The Set-up consists of two sided clear fabrication. Water is fed througha nozzle and discharged vertically to strike a target carried on a stem, which extendsthrough the cover. A weight carrier is mounted on the upper end of the stem. The deadweight of the moving parts is counter balanced by a compression spring. The verticalforce exe..

Quickview

METACENTRIC HEIGHT

(0)
₹2.0

DESCRIPTION:- A pontoon is allowed to float in a small tank having a transparent side.Removable steel strips placed in the model for the purpose of changing the weight of themodel. Displacement of weight is measured with the help of a scale. By means of apendulum (consisting of a weight suspended to a long pointer) the angle of tilt can bemeasured ..

Quickview

ORIFICE & MOUTHPIECES

(0)
₹2.0

An orifice is an opening made in the side or bottom of tank, having a closed perimeter,through which the fluid may be discharged. A mouthpiece is short tube fitted to a same sizecircular opening provided in a tank so that fluid may be discharged through it. Orifice andmouthpiece are used to measure the rate of flow of liquid. The apparatus is desig..

Quickview

PITOT STATIC TUBE

(0)
₹2.0

DESCRIPTION:- A Pitot tube is used to measure the local velocity at a given point in theflow stress. A Pitot tube of standard design made of copper / SS is supplied and is fixedbelow Vernier scale. The Vernier scale is capable to measure the position of Pitot tube intransparent pipe section. The pipe has a flow control valve to regulate the flow. A..

Quickview

REYNOLD'S APPARATUS

(0)
₹2.0

The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatusconsists of a glass tube which one end having bell mouth entrance connected to a watertank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flowrate of water can be measured with the help of Measuring Cylinder and Stop Watch,supplied wi..

Quickview

STUDY OF PIPE FITTING

(0)
₹2.0

The Set-up consists of a ½ bend and elbow, a sudden expansion & sudden contraction fittingfrom 15 mm to 25 mm, ball valve and gate valve. Pressure tapings are provided at inlet andoutlet of these fittings under test. A differential manometer fitted in the line gives pressureloss of individual fitting. Present Set-up is self-contained water re-c..

Quickview

VENTURIMETER / ORIFICEMETER SETUP

(0)
₹2.0

The apparatus consists of two pipelines emerging out from a common manifold. Onepipeline contain a Venturimeter, second contains an Orifice. The pressure tapings from theVenturimeter and Orificemeter are taken to differential manometer to measure pressuredifference. The Venturimeter and Orificemeter are connected in parallel and anyone of themcan b..

Showing 1 to 12 of 12 (1 Pages)