Frequency of AC signals by sonometer

Frequency of AC signals by sonometer

0 reviews 0 sold. Only 100 remain
₹2.0
₹2.0
Tax ₹0.0
Product Code: PY-201
Stock In Stock
Viewed 2007 times

Product Description

 Frequency of AC signals by sonometer

To Find The Frequency Of Ac Mains By Sonometer. 


APPARATUS USED


1. SONOMETER

A. box 
45" x 4" x 4" with meter scales one meter long sub-divided in millimeters.

B. Wires
One brass(S.W. G. 26 ) and steel wire(SWG 24) attached to a fixed bridge and tensioned by fine adjustment pegs; 


2. Electromagnet 
(a copper wire of 36 SWG is wound (approx. 30 -50 turns) on a metal rod with a non inductive handle having two terminals for connecting transformer.

3. Step down transformer of fixed voltage( 6 V) current 1 Amps is fitted on wooden board with two terminals, operates on 220V AC.

4. Iron stand with clamp and boss Head

5. Slotted weight 5 x 500 gm

Working:

When this electromagnet is supported over wires of a Sonometer, the wires starts vibrating by adjusting the tension and the bridge position maximum resonance can be obtained. 